Net Radiation - Net Radiometer (NR-Lite)

From Experimental Hydrology Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Net-Radiometer NR Lite

Parameter to be measured:

Net Radiation (spectral range 0.2-100µm): The net radiation is the energy balance between incoming short-wave and long-wave infrared (IR) radiation relative to surface reflected short-wave and outgoing long-wave IR radiation.

Method:

The NR-Lite sensor is a thermopile sensor. It has on both sides an black absorber and the sensors outputs a voltage. The vaoltage is proportional to the radiation

Equipment:

  • NR-Lite sensor
  • Mounting gear
  • Logger

Advantages:

  • Cheap compared to other net radiometers like the CNR 1 from Kipp & Zonen
  • resistant
  • measures the short and longwave radiation in one sensor

Disadvantages:

  • not as precise as CNR 1 or comparable other sensors
  • sensitive to wind speed

What to watch out for:

  • keep the sensor clean


Problems/Questions:

Links

Projects that used the above equipment: HYGRA – The effect of water storage variations on in-situ gravity measurements and their use for hydrology

Manufacturer: Kipp & Zonen

Dealer: Campbell Scientific Thies Clima

Manuals and other resources:

NR-Lite Manual

References

The following paper compares the NR Lite with supposedly more precise instrumentation. Interesting conclusions. Douglas R. Cobos, John M. Baker (2003) Evaluation and Modification of a Domeless Net Radiometer, Agron. J. 95:177–183 (http://agron.scijournals.org/cgi/reprint/95/1/177.pdf)