Difference between revisions of "Soil moisture - impedance method (Theta Probe)"
(New page: ==Parameter to be measured:== Soil moisture ==Method:== Impedance-methode ==Equipment:== *Delta-T Device: Theta-Probe (ML2x) *Stevens: Hydra Probe II ==Advantages:== *easy and fast meas...) |
|||
Line 35: | Line 35: | ||
==References== | ==References== | ||
Blonquist, JM; Jones, SB; Robinson, DA. 2005. Standardizing characterization of electromagnetic water content sensors: Part 2. Evaluation of seven sensing systems. VADOSE ZONE JOURNAL 4 (4): 1059-1069. | Blonquist, JM; Jones, SB; Robinson, DA. 2005. Standardizing characterization of electromagnetic water content sensors: Part 2. Evaluation of seven sensing systems. VADOSE ZONE JOURNAL 4 (4): 1059-1069. | ||
+ | |||
Gaskin, GJ; Miller, JD. 1996. Measurement of soil water content using a simplified impedance measuring technique. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH 63 (2): 153-159. | Gaskin, GJ; Miller, JD. 1996. Measurement of soil water content using a simplified impedance measuring technique. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH 63 (2): 153-159. | ||
+ | |||
Miller, JD; Gaskin, GJ; Anderson, HA. 1997. From drought to flood: Catchment responses revealed using novel soil water probes. HYDROLOGICAL PROCESSES 11 (5): 533-541. | Miller, JD; Gaskin, GJ; Anderson, HA. 1997. From drought to flood: Catchment responses revealed using novel soil water probes. HYDROLOGICAL PROCESSES 11 (5): 533-541. | ||
+ | |||
Seyfried, MS; Murdock, MD. 2004. Measurement of soil water content with a 50-MHz soil dielectric sensor. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL 68 (2): 394-403. | Seyfried, MS; Murdock, MD. 2004. Measurement of soil water content with a 50-MHz soil dielectric sensor. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL 68 (2): 394-403. | ||
[[Category:Equipment]] | [[Category:Equipment]] | ||
[[Category: Soil Moisture]] | [[Category: Soil Moisture]] |
Revision as of 15:18, 10 September 2007
Parameter to be measured:
Soil moisture
Method:
Impedance-methode
Equipment:
- Delta-T Device: Theta-Probe (ML2x)
- Stevens: Hydra Probe II
Advantages:
- easy and fast measurement of punctual soil moisture
- manual as well as continuously logged measurements possible
Disadvantages:
- Each sensor has to be calibrated
- careful application of probe in stony soils
- Underestimating of permittivity in media with low permitivity (ε < 40, clay and organic soils)
What to watch out for:
- Good contact between probe and medium has to be proofed
Problems/Questions:
Links
Other related web sites:
- John Miller Theta Probe: Theta Probe ML2X Principles of operation and application
- Delta-T Devices: User Manual
- Stevens: Manual & Theory
References
Blonquist, JM; Jones, SB; Robinson, DA. 2005. Standardizing characterization of electromagnetic water content sensors: Part 2. Evaluation of seven sensing systems. VADOSE ZONE JOURNAL 4 (4): 1059-1069.
Gaskin, GJ; Miller, JD. 1996. Measurement of soil water content using a simplified impedance measuring technique. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH 63 (2): 153-159.
Miller, JD; Gaskin, GJ; Anderson, HA. 1997. From drought to flood: Catchment responses revealed using novel soil water probes. HYDROLOGICAL PROCESSES 11 (5): 533-541.
Seyfried, MS; Murdock, MD. 2004. Measurement of soil water content with a 50-MHz soil dielectric sensor. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL 68 (2): 394-403.