==Parameter to be measured:==
 
==Parameter to be measured:==
 
Discharge, flow velocity, depth
 
Discharge, flow velocity, depth
 
+
{| align="right"
 +
|[[Image:riv_surv_marginal.JPG|right|220px|RiverSurveyor]]
 +
|}
 
==Method:==
 
==Method:==
 
Acoustic Doppler Current Profiling
 
Acoustic Doppler Current Profiling
Line 22: Line 24:
 
* measurement continues even when connection is lost
 
* measurement continues even when connection is lost
 
* configurable options (communication: BT/radio, GPS: GPS/GNSS, platform: low /high velocity/remote controled)
 
* configurable options (communication: BT/radio, GPS: GPS/GNSS, platform: low /high velocity/remote controled)
 +
 +
{| align="right"
 +
|[[Image:ADCP.png|right|400px|flow velocities]]
 +
|}
  
 
==Disadvantages:==
 
==Disadvantages:==
Line 30: Line 36:
 
* transversal speed must be lower than flow velocity
 
* transversal speed must be lower than flow velocity
 
* deeply incised riverbeds and vegetation may strongly impair GPS reception
 
* deeply incised riverbeds and vegetation may strongly impair GPS reception
* The product basic GPS-setting is advertised as "dGPS", but is merely ordinary SBAS-corrected GPS. True dGPS-solutions (base - rover) do exist, but post processing is not supported. Other GNSS-receivers may be customized.
+
* The product basic GPS-setting is advertised as "dGPS", but is merely ordinary SBAS-corrected GPS. True dGPS-solutions (base - rover) do exist, but post processing is not supported. Other GNSS-receivers may be customized with extra hardware.
 
* Stratification of temperature and salinity affects the depth measurement. This can be corrected for when a CastAway CTS sensor is used. Import of data otherwise acquired is not supported.
 
* Stratification of temperature and salinity affects the depth measurement. This can be corrected for when a CastAway CTS sensor is used. Import of data otherwise acquired is not supported.
 +
* The built-in temperature sensor shows strong thermal inertia, ie reacts slowly. In our test, an initial temperature difference of only 4 K (10°C to 6°C) took ~1 hour to equilibrate. The endpoint temperature was still 2 K above conventional measurements.
 +
* When the sensor is not properly connected to the PCA, the latter appears fully operational, but does not connect via radio.
  
 
==Problems/Questions:==
 
==Problems/Questions:==

Revision as of 14:18, 5 January 2016

RiverSurveyor

Parameter to be measured:

Discharge, flow velocity, depth

RiverSurveyor

Method:

Acoustic Doppler Current Profiling

Equipment:

  • sensor (M9)
  • processing unit (data processing, storage, GPS receiver, communication)
  • GPS antenna
  • platform (raft)

Advantages:

  • high resolution velocity profile of river transect (up to 128 cells)
  • dual frequency sensor covers wide range of depths (0.3 - 40 m)
  • position can be estimated via both bottom tracking and GPS
  • intuitive software for both PC and Windows Mobile
  • measurement continues even when connection is lost
  • configurable options (communication: BT/radio, GPS: GPS/GNSS, platform: low /high velocity/remote controled)
flow velocities

Disadvantages:

  • platform is quite bulky
  • price

What to watch out for:

  • transversal speed must be lower than flow velocity
  • deeply incised riverbeds and vegetation may strongly impair GPS reception
  • The product basic GPS-setting is advertised as "dGPS", but is merely ordinary SBAS-corrected GPS. True dGPS-solutions (base - rover) do exist, but post processing is not supported. Other GNSS-receivers may be customized with extra hardware.
  • Stratification of temperature and salinity affects the depth measurement. This can be corrected for when a CastAway CTS sensor is used. Import of data otherwise acquired is not supported.
  • The built-in temperature sensor shows strong thermal inertia, ie reacts slowly. In our test, an initial temperature difference of only 4 K (10°C to 6°C) took ~1 hour to equilibrate. The endpoint temperature was still 2 K above conventional measurements.
  • When the sensor is not properly connected to the PCA, the latter appears fully operational, but does not connect via radio.

Problems/Questions:

  • How does sediment concentration affect the measurements?

Price:

35000 € with basic GPS option and Hydroboard (2013, Germany)

Links

Projects that used the above equipment:


Other related web sites:


References