Difference between revisions of "Discharge - Current meter Ott C2"
Jump to navigation
Jump to search
m |
|||
Line 1: | Line 1: | ||
+ | {| align="right" | ||
+ | |[[Image:C2.JPG|right|400px|ADC]] | ||
+ | |} | ||
+ | |||
==Parameter to be measured:== | ==Parameter to be measured:== | ||
Flow velocity (discharge) | Flow velocity (discharge) |
Revision as of 13:48, 8 December 2014
Parameter to be measured:
Flow velocity (discharge)
Method:
propeller
Equipment:
C2:
- propellers
- axle
- wading rod
counting unit (e.g. Ott Z400)
Advantages:
- simple no-fuss mechanics
- "sensor" (propeller) response is directly visual
- comparatively small case including wading rods
Disadvantages:
- poor response in low velocities
- maintainance of ball bearings (oil)
- mechanical vulnarability
- no immediate calculation of discharge, no data storage?
What to watch out for:
- submerged weeds, low velocities, piranhas
Price:
- ~ 8000 € (2008)
Links
Discharge - comparison of measurements (C2, Flowtracker, Flowsens, ADC, tracer, dipping rod)
Other related web sites:
Projects that used the above equipment: http://brandenburg.geoecology.uni-potsdam.de/projekte/sesam/