Soil moisture - TDR (TRIME tube access probe)

From Experimental Hydrology Wiki
Revision as of 19:46, 16 December 2008 by Thomas (talk | contribs)
Jump to navigation Jump to search

Parameter to be measured:

Soil moisture

Method:

Trime TDR-method

Equipment:

  • IMKO: T3 tube probe

Advantages:

  • easy and fast measurement in access tube to the depth of the access tube
  • manual as well as continuously logged measurements possible, but if logged measurement only in one depth
  • accuracy comparable to neutron probes

Disadvantages:

  • installation of access tube in gravel rich soils is complicated and the IMKO drill is useless in this soils.

What to watch out for:

  • The measurement volume of the probe is not circularly around the probe. To measure the mean water content of one depth requires measurement in different directions.

Problems/Questions:

Links

Other related web sites:


References

Evett, SR, Tolk, JA, Howell, TQ 2006. Soil profile water content determination: Sensor accuracy, axial response, calibration, temperature dependence, and precision. Vadose Zone 5, 894–907.