Soil moisture - capacitance (TMS)

From Experimental Hydrology Wiki
Revision as of 09:26, 26 September 2013 by Thomas (talk | contribs) (Created page with " ==Parameter to be measured:== Soil moisture, soil temperature ==Method:== Capacitance ==Equipment:== : temperature measurement with sensor MAXIM/DALLAS Semiconductor DS7505...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Parameter to be measured:

Soil moisture, soil temperature

Method:

Capacitance

Equipment:

temperature measurement with sensor MAXIM/DALLAS Semiconductor DS7505U+, with resolution of 0.0625 °C and with accuracy of ±0.5 °C
soil moisture measurement based on capacity technique in the frequency of 100-200MHz
integrated data loggers of 32MBit

Advantages:

  • cheap
  • Easy to install

Disadvantages:

  • Calibration needed
  • Small measurement volume compared to other sensors
  • not for portable usage designed
  • life time is short (in the first two years errors of the measured values start to increase, especially the temperature sensor is effected)

What to watch out for:

  • Careful installation, air gaps have a sustainable influence on the measurement compared to other sensors because of the small measurement volume

Problems/Questions:

Links

Projects that used the above equipment:

Other related web sites: