Difference between revisions of "Soil moisture - capacitance (HS10 Decagon)"

From Experimental Hydrology Wiki
Jump to navigation Jump to search
(New page: ==Parameter to be measured:== Soil moisture ==Method:== Capacitance ==Equipment:== *HS10 Decagon :Effective range of temperature: -40°C - +50°C :Effective range of soil moisture: 0 - 5...)
 
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
[[Image: Decagon_10HS.jpg |right|250px|]]
 
==Parameter to be measured:==
 
==Parameter to be measured:==
 
Soil moisture
 
Soil moisture
Line 29: Line 30:
  
 
Other related web sites:
 
Other related web sites:
*[http://www.decagon.com/products/sensors/soil-moisture-sensors/10hs-soil-moisture-large-area-of-influence/ HS10 by DECAGON]
+
*[http://www.decagon.com/products/sensors/soil-moisture-sensors/10hs-soil-moisture-large-area-of-influence/ HS10 at DECAGON]
  
 
==References==
 
==References==
 
+
*  Kargas, G., Soulis, K. (2012): Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor, J. Irrig. Drain Eng., 138(7), 632–641. DOI: 10.1061/(ASCE)IR.1943-4774.0000449.
 +
* Mittelbach, H., Lehner, I., Seneviratne, S.I. (2012): Comparison of four soil moisture sensor types under field conditions in Switzerland, J of Hydrology 430-431, 39-49, DOI: 10.1016/j.jhydrol.2012.01.041.
  
 
[[Category:Equipment]]
 
[[Category:Equipment]]
 
[[Category:Soil Moisture]]
 
[[Category:Soil Moisture]]

Latest revision as of 10:51, 2 November 2012

Decagon 10HS.jpg

Parameter to be measured:

Soil moisture

Method:

Capacitance

Equipment:

  • HS10 Decagon
Effective range of temperature: -40°C - +50°C
Effective range of soil moisture: 0 - 57 % volumetric water content
Accuracy: ±3% without calibration, ±1% - ±2% with calibration

Advantages:

  • Relatively cheap
  • Easy to install
  • Compatible with many loggers

Disadvantages:

  • Calibration needed
  • Small measurement volume compared to other sensors

What to watch out for:

  • Careful installation, air gaps have a sustainable influence on the measurement compared to other sensors because of the small measurement volume
  • Probe is tenderly and will break, if it is pushed in resistive media.

Problems/Questions:

Links

Projects that used the above equipment:

Other related web sites:

References

  • Kargas, G., Soulis, K. (2012): Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor, J. Irrig. Drain Eng., 138(7), 632–641. DOI: 10.1061/(ASCE)IR.1943-4774.0000449.
  • Mittelbach, H., Lehner, I., Seneviratne, S.I. (2012): Comparison of four soil moisture sensor types under field conditions in Switzerland, J of Hydrology 430-431, 39-49, DOI: 10.1016/j.jhydrol.2012.01.041.