Parameter to be measured:

Soil moisture

Method:

Capacitance

Equipment:

  • HS10 Decagon
Effective range of temperature: -40°C - +50°C
Effective range of soil moisture: 0 - 57 % volumetric water content
Accuracy: ±3% without calibration, ±1% - ±2% with calibration

Advantages:

  • Relatively cheap
  • Easy to install
  • Compatible with many loggers

Disadvantages:

  • Calibration needed
  • Small measurement volume compared to other sensors

What to watch out for:

  • Careful installation, air gaps have a sustainable influence on the measurement compared to other sensors because of the small measurement volume
  • Probe is tenderly and will break, if it is pushed in resistive media.

Problems/Questions:

Links

Projects that used the above equipment:

Other related web sites:

References