Difference between revisions of "Soil moisture - capacitance (TMS)"
Jump to navigation
Jump to search
(6 intermediate revisions by the same user not shown) | |||
Line 40: | Line 40: | ||
Other related web sites: | Other related web sites: | ||
*[http://www.tomst.com/site/de/tms.html TOMST®] | *[http://www.tomst.com/site/de/tms.html TOMST®] | ||
− | *[http://www.tomst.com/tms/ | + | *[http://www.tomst.com/tms/Home.html TMS3 TOMST Measuring System - Station for spatially distributed measurements of soil moisture and ambient temperature in vast fields] |
+ | *[http://www.tomst.com/tms/Software.html TMS software and calibration set for typical soils] | ||
+ | |||
+ | ==References== | ||
+ | *Wild, J., Kopecký, M., Zmeškalová, J., Hadincová, V., Trachtová, P., Nováková, O., Štípek, A., Šanda, M., Haase, T., Field monitoring of microclimate: new combined thermal and soil moisture standalone unit | ||
+ | *[http://article.sciencepublishinggroup.com/pdf/10.11648.j.earth.20130202.15.pdf Hernández, J.A.C. et al., 2013. Unsaturated volcanic tephra and its effect for soil movement in El Salvado. Earth Science 2(2), 58-65, DOI: 10.11648/j.earth.20130202.1] | ||
+ | *[http://botanika.prf.jcu.cz/thesis/pdf/SvetlikovaP_Mgr13.pdf Světlíková, P., 2012. Impact of local heat leakage on vegetation and participation of non-native species. Master thesis, České Budějovice, CZ] | ||
− | |||
− | |||
[[Category:Equipment]] | [[Category:Equipment]] | ||
[[Category:Soil Moisture]] | [[Category:Soil Moisture]] | ||
[[Category:Temperature]] | [[Category:Temperature]] |
Latest revision as of 16:16, 8 December 2016
Parameter to be measured:
Soil moisture, soil, surface and air temperature
Method:
Capacitance
Equipment:
- temperature measurement with sensor MAXIM/DALLAS Semiconductor DS7505U+, with resolution of 0.0625 °C and with accuracy of ±0.5 °C
- soil moisture measurement based on capacity technique in the frequency of 100-200MHz
- integrated data loggers of 32MBit
Advantages:
- stand alone system
- cheap
- Easy to install
Disadvantages:
- Calibration needed
- Small measurement volume compared to other sensors
- Actual Software is less comfortable
- Connection between readout unit and probe can be improoved
What to watch out for:
- Careful installation, air gaps have a sustainable influence on the measurement compared to other sensors because of the small measurement volume
Problems/Questions:
Price:
80 € (2013, Europe)
Links
Projects that used the above equipment:
Other related web sites:
- TOMST®
- TMS3 TOMST Measuring System - Station for spatially distributed measurements of soil moisture and ambient temperature in vast fields
- TMS software and calibration set for typical soils
References
- Wild, J., Kopecký, M., Zmeškalová, J., Hadincová, V., Trachtová, P., Nováková, O., Štípek, A., Šanda, M., Haase, T., Field monitoring of microclimate: new combined thermal and soil moisture standalone unit
- Hernández, J.A.C. et al., 2013. Unsaturated volcanic tephra and its effect for soil movement in El Salvado. Earth Science 2(2), 58-65, DOI: 10.11648/j.earth.20130202.1
- Světlíková, P., 2012. Impact of local heat leakage on vegetation and participation of non-native species. Master thesis, České Budějovice, CZ