[[Image:ProfileProbe_PR1.jpg|right|400px|PR1 profile probe]]
 
[[Image:ProfileProbe_PR1.jpg|right|400px|PR1 profile probe]]
 
==Parameter to be measured:==
 
==Parameter to be measured:==
Soil moisture. Permanent soil moisture monitoring along a soil profile.
+
Soil moisture. Continuous soil moisture monitoring along a soil profile.
  
 
==Method:==
 
==Method:==
Line 10: Line 10:
  
 
==Advantages:==
 
==Advantages:==
*measures soil moisture in 4-6 depths with a maximum depth of 1m.
+
*measures soil moisture in 4-6 depths with a maximum depth of 1 m.
*manual as well as continuously logging measurements possible
+
*manual as well as continuously logging measurements are possible
  
 
==Disadvantages:==
 
==Disadvantages:==
Line 17: Line 17:
 
*The application of probe in stony soils is very limited
 
*The application of probe in stony soils is very limited
 
*The soil is always disturbed after installing the pipe. So you have to wait at least a month to get "real" measurements
 
*The soil is always disturbed after installing the pipe. So you have to wait at least a month to get "real" measurements
 +
*Preferential flow along the probe can be initiated, so that the probe measures always wetter states compared to the surrounding media.
 +
*In gravel rich soils installation is complicate.
 +
*There is a temperature affect on the soil moisture signal.
 +
*If probe is placed manually prior to each measurement, it is unlikely to make good contact with the soil, resulting in a dry bias to the measurements.
  
 
==What to watch out for:==
 
==What to watch out for:==
Line 23: Line 27:
 
*Test each sensor along the probe by covering one after the other with a wet cloth and taking a measurement, just to see if there is a reaction.
 
*Test each sensor along the probe by covering one after the other with a wet cloth and taking a measurement, just to see if there is a reaction.
 
*Look at the data carefully. Test if there is a preferential flow between pipe and soil.
 
*Look at the data carefully. Test if there is a preferential flow between pipe and soil.
 +
*The inner surface of the pipe has to be kept absolutly dry, otherwise measurement failure can occur.
 +
*When teh analogue version is operated with a DeltaT-logger, it provides teh option to log the values as raw voltage or as soil moisture. When choosing the raw voltage, make sure all the ground terminals of the single sensor rings are connected with a bridge in the logger. Otherwise, strange drifts or noise in all but the signals from ring #1 may occur later in the records.
  
 
==Problems/Questions:==
 
==Problems/Questions:==
Line 29: Line 35:
 
==Links==
 
==Links==
 
Projects that used the above equipment:
 
Projects that used the above equipment:
*http://brandenburg.geoecology.uni-potsdam.de/projekte/malalcahuello/index.php
+
*[http://brandenburg.geoecology.uni-potsdam.de/projekte/malalcahuello/index.php Identification of runoff processes in a small undisturbed catchment in the Chilean Andes - Experimental study and modelling]
 +
* [http://www.gfz-potsdam.de/en/research/organizational-units/departments-of-the-gfz/department-5/hydrology/projects/hygra/ HYGRA: The effect of water storage variations on in-situ gravity measurements and their use]
 +
* [http://www.comtess.uni-oldenburg.de/ COMTESS]
 +
* [https://www.uni-potsdam.de/de/cosmicsense/ Cosmic Sense]
  
 
Other related web sites:
 
Other related web sites:
*http://en.wikipedia.org/wiki/Frequency_domain_sensor
+
*[http://en.wikipedia.org/wiki/Frequency_domain_sensor Wikipedia FDR]
  
*Delta-T Devices: [http://www.delta-t.co.uk/cgi-bin/attach.cgi?item=faq2005092821653.2 Quick Start Guide]
+
*Delta-T Devices Eijkelkamp Agrisearch Equipment: [http://pkd.eijkelkamp.com/Portals/2/Eijkelkamp/Files/Manuals/M1-142682e%20Profile%20probe%20PR2.pdf User Manual]
*Delta-T Devices: [http://www.delta-t.co.uk/cgi-bin/attach.cgi?item=faq2005092821658.2 User Manual]
+
*Delta-T Devices: [http://www.delta-t.co.uk/product-display.asp?id=939&div=Soil%20Science&cat= User Manual]
*Delta-T Devices: [http://www.delta-t.co.uk/cgi-bin/attach.cgi?item=faq2005110304509.2 Augering Manual]
+
*Delta-T Devices: [ftp://ftp.dynamax.com/manuals/PR2_QSG.pdf Quick start guide]
 +
*Delta-T Devices: [ftp://ftp.dynamax.com/manuals/Augering_Manual.pdf Augering Manual]
  
 
==References==
 
==References==
 +
*Evett, SR., Tolk, JA., Howell, TQ., 2006: Soil profile water content determination: Sensor accuracy, axial response, calibration, temperature dependence, and precision. Vadose Zone 5, 894–907.
 +
 +
*Blume,T., Zehe, E., Bronstert, A., 2009: [http://www.hydrol-earth-syst-sci.net/13/1215/2009/hess-13-1215-2009.html Use of soil moisture dynamics and patterns at different spatio-temporal scales for the investigation of subsurface flow processes.] Hydrol. Earth Syst. Sci., 13, 1215–1234.
 +
  
  
 
[[Category:Equipment]]
 
[[Category:Equipment]]
 
[[Category:Soil Moisture]]
 
[[Category:Soil Moisture]]

Latest revision as of 10:08, 16 August 2023

PR1 profile probe

Parameter to be measured:

Soil moisture. Continuous soil moisture monitoring along a soil profile.

Method:

FDR - frequency domain reflectometry, capacitive

Equipment:

  • Delta-T Device: Profile probe (PR1/PR2)

Advantages:

  • measures soil moisture in 4-6 depths with a maximum depth of 1 m.
  • manual as well as continuously logging measurements are possible

Disadvantages:

  • Each probe has to be calibrated (however, it does come with a standard calibration for organic and for mineral soil)
  • The application of probe in stony soils is very limited
  • The soil is always disturbed after installing the pipe. So you have to wait at least a month to get "real" measurements
  • Preferential flow along the probe can be initiated, so that the probe measures always wetter states compared to the surrounding media.
  • In gravel rich soils installation is complicate.
  • There is a temperature affect on the soil moisture signal.
  • If probe is placed manually prior to each measurement, it is unlikely to make good contact with the soil, resulting in a dry bias to the measurements.

What to watch out for:

  • The access tube for the probe needs to be very carefully installed. There should be no air gap between the access tube and the soil!
  • If you have access tubes installed in the field, but are taking only manual measurements from time to time (i.e. the probe is not continuously inside the access tube) make sure to check for condensated water inside the tube before making measurements.
  • Test each sensor along the probe by covering one after the other with a wet cloth and taking a measurement, just to see if there is a reaction.
  • Look at the data carefully. Test if there is a preferential flow between pipe and soil.
  • The inner surface of the pipe has to be kept absolutly dry, otherwise measurement failure can occur.
  • When teh analogue version is operated with a DeltaT-logger, it provides teh option to log the values as raw voltage or as soil moisture. When choosing the raw voltage, make sure all the ground terminals of the single sensor rings are connected with a bridge in the logger. Otherwise, strange drifts or noise in all but the signals from ring #1 may occur later in the records.

Problems/Questions:

What is the exact difference between the old version (PR1) and the new version (PR2) of the probe? (see discussion page to this article)

Links

Projects that used the above equipment:

Other related web sites:

References

  • Evett, SR., Tolk, JA., Howell, TQ., 2006: Soil profile water content determination: Sensor accuracy, axial response, calibration, temperature dependence, and precision. Vadose Zone 5, 894–907.